QuotaLimit
class QuotaLimit extends Message
QuotaLimit
defines a specific limit that applies over a specified duration
for a limit type. There can be at most one limit for a duration and limit
type combination defined within a QuotaGroup
.
Protobuf type Google\Api\QuotaLimit
Methods
No description
Name of the quota limit. The name is used to refer to the limit when overriding the default limit on per-consumer basis.
Name of the quota limit. The name is used to refer to the limit when overriding the default limit on per-consumer basis.
Optional. User-visible, extended description for this quota limit.
Optional. User-visible, extended description for this quota limit.
Default number of tokens that can be consumed during the specified duration. This is the number of tokens assigned when a client application developer activates the service for his/her project.
Default number of tokens that can be consumed during the specified duration. This is the number of tokens assigned when a client application developer activates the service for his/her project.
Maximum number of tokens that can be consumed during the specified duration. Client application developers can override the default limit up to this maximum. If specified, this value cannot be set to a value less than the default limit. If not specified, it is set to the default limit.
Maximum number of tokens that can be consumed during the specified duration. Client application developers can override the default limit up to this maximum. If specified, this value cannot be set to a value less than the default limit. If not specified, it is set to the default limit.
Free tier value displayed in the Developers Console for this limit.
Free tier value displayed in the Developers Console for this limit.
Duration of this limit in textual notation. Example: "100s", "24h", "1d".
Duration of this limit in textual notation. Example: "100s", "24h", "1d".
The name of the metric this quota limit applies to. The quota limits with the same metric will be checked together during runtime. The metric must be defined within the service config.
The name of the metric this quota limit applies to. The quota limits with the same metric will be checked together during runtime. The metric must be defined within the service config.
Specify the unit of the quota limit. It uses the same syntax as [Metric.unit][]. The supported unit kinds are determined by the quota backend system.
Specify the unit of the quota limit. It uses the same syntax as [Metric.unit][]. The supported unit kinds are determined by the quota backend system.
Tiered limit values. Also allows for regional or zone overrides for these values if "/{region}" or "/{zone}" is specified in the unit field.
Tiered limit values. Also allows for regional or zone overrides for these values if "/{region}" or "/{zone}" is specified in the unit field.
User-visible display name for this limit.
User-visible display name for this limit.
Details
at line 175
__construct()
at line 199
string
getName()
Name of the quota limit. The name is used to refer to the limit when overriding the default limit on per-consumer basis.
For group-based quota limits, the name must be unique within the quota group. If a name is not provided, it will be generated from the limit_by and duration fields. For metric-based quota limits, the name must be provided, and it must be unique within the service. The name can only include alphanumeric characters as well as '-'. The maximum length of the limit name is 64 characters. The name of a limit is used as a unique identifier for this limit. Therefore, once a limit has been put into use, its name should be immutable. You can use the display_name field to provide a user-friendly name for the limit. The display name can be evolved over time without affecting the identity of the limit.
Generated from protobuf field string name = 6;
at line 223
setName(string $var)
Name of the quota limit. The name is used to refer to the limit when overriding the default limit on per-consumer basis.
For group-based quota limits, the name must be unique within the quota group. If a name is not provided, it will be generated from the limit_by and duration fields. For metric-based quota limits, the name must be provided, and it must be unique within the service. The name can only include alphanumeric characters as well as '-'. The maximum length of the limit name is 64 characters. The name of a limit is used as a unique identifier for this limit. Therefore, once a limit has been put into use, its name should be immutable. You can use the display_name field to provide a user-friendly name for the limit. The display name can be evolved over time without affecting the identity of the limit.
Generated from protobuf field string name = 6;
at line 237
string
getDescription()
Optional. User-visible, extended description for this quota limit.
Should be used only when more context is needed to understand this limit
than provided by the limit's display name (see: display_name
).
Generated from protobuf field string description = 2;
at line 250
setDescription(string $var)
Optional. User-visible, extended description for this quota limit.
Should be used only when more context is needed to understand this limit
than provided by the limit's display name (see: display_name
).
Generated from protobuf field string description = 2;
at line 269
int|string
getDefaultLimit()
Default number of tokens that can be consumed during the specified duration. This is the number of tokens assigned when a client application developer activates the service for his/her project.
Specifying a value of 0 will block all requests. This can be used if you are provisioning quota to selected consumers and blocking others. Similarly, a value of -1 will indicate an unlimited quota. No other negative values are allowed. Used by group-based quotas only.
Generated from protobuf field int64 default_limit = 3;
at line 287
setDefaultLimit(int|string $var)
Default number of tokens that can be consumed during the specified duration. This is the number of tokens assigned when a client application developer activates the service for his/her project.
Specifying a value of 0 will block all requests. This can be used if you are provisioning quota to selected consumers and blocking others. Similarly, a value of -1 will indicate an unlimited quota. No other negative values are allowed. Used by group-based quotas only.
Generated from protobuf field int64 default_limit = 3;
at line 305
int|string
getMaxLimit()
Maximum number of tokens that can be consumed during the specified duration. Client application developers can override the default limit up to this maximum. If specified, this value cannot be set to a value less than the default limit. If not specified, it is set to the default limit.
To allow clients to apply overrides with no upper bound, set this to -1, indicating unlimited maximum quota. Used by group-based quotas only.
Generated from protobuf field int64 max_limit = 4;
at line 322
setMaxLimit(int|string $var)
Maximum number of tokens that can be consumed during the specified duration. Client application developers can override the default limit up to this maximum. If specified, this value cannot be set to a value less than the default limit. If not specified, it is set to the default limit.
To allow clients to apply overrides with no upper bound, set this to -1, indicating unlimited maximum quota. Used by group-based quotas only.
Generated from protobuf field int64 max_limit = 4;
at line 340
int|string
getFreeTier()
Free tier value displayed in the Developers Console for this limit.
The free tier is the number of tokens that will be subtracted from the billed amount when billing is enabled. This field can only be set on a limit with duration "1d", in a billable group; it is invalid on any other limit. If this field is not set, it defaults to 0, indicating that there is no free tier for this service. Used by group-based quotas only.
Generated from protobuf field int64 free_tier = 7;
at line 357
setFreeTier(int|string $var)
Free tier value displayed in the Developers Console for this limit.
The free tier is the number of tokens that will be subtracted from the billed amount when billing is enabled. This field can only be set on a limit with duration "1d", in a billable group; it is invalid on any other limit. If this field is not set, it defaults to 0, indicating that there is no free tier for this service. Used by group-based quotas only.
Generated from protobuf field int64 free_tier = 7;
at line 373
string
getDuration()
Duration of this limit in textual notation. Example: "100s", "24h", "1d".
For duration longer than a day, only multiple of days is supported. We support only "100s" and "1d" for now. Additional support will be added in the future. "0" indicates indefinite duration. Used by group-based quotas only.
Generated from protobuf field string duration = 5;
at line 388
setDuration(string $var)
Duration of this limit in textual notation. Example: "100s", "24h", "1d".
For duration longer than a day, only multiple of days is supported. We support only "100s" and "1d" for now. Additional support will be added in the future. "0" indicates indefinite duration. Used by group-based quotas only.
Generated from protobuf field string duration = 5;
at line 403
string
getMetric()
The name of the metric this quota limit applies to. The quota limits with the same metric will be checked together during runtime. The metric must be defined within the service config.
Used by metric-based quotas only.
Generated from protobuf field string metric = 8;
at line 417
setMetric(string $var)
The name of the metric this quota limit applies to. The quota limits with the same metric will be checked together during runtime. The metric must be defined within the service config.
Used by metric-based quotas only.
Generated from protobuf field string metric = 8;
at line 455
string
getUnit()
Specify the unit of the quota limit. It uses the same syntax as [Metric.unit][]. The supported unit kinds are determined by the quota backend system.
The Google Service Control supports the following unit components: * One of the time intevals: * "/min" for quota every minute. * "/d" for quota every 24 hours, starting 00:00 US Pacific Time. * Otherwise the quota won't be reset by time, such as storage limit. * One and only one of the granted containers: * "/{organization}" quota for an organization. * "/{project}" quota for a project. * "/{folder}" quota for a folder. * "/{resource}" quota for a universal resource. * Zero or more quota segmentation dimension. Not all combos are valid. * "/{region}" quota for every region. Not to be used with time intervals. * Otherwise the resources granted on the target is not segmented. * "/{zone}" quota for every zone. Not to be used with time intervals. * Otherwise the resources granted on the target is not segmented. * "/{resource}" quota for a resource associated with a project or org. Here are some examples: * "1/min/{project}" for quota per minute per project. * "1/min/{user}" for quota per minute per user. * "1/min/{organization}" for quota per minute per organization. Note: the order of unit components is insignificant. The "1" at the beginning is required to follow the metric unit syntax. Used by metric-based quotas only.
Generated from protobuf field string unit = 9;
at line 492
setUnit(string $var)
Specify the unit of the quota limit. It uses the same syntax as [Metric.unit][]. The supported unit kinds are determined by the quota backend system.
The Google Service Control supports the following unit components: * One of the time intevals: * "/min" for quota every minute. * "/d" for quota every 24 hours, starting 00:00 US Pacific Time. * Otherwise the quota won't be reset by time, such as storage limit. * One and only one of the granted containers: * "/{organization}" quota for an organization. * "/{project}" quota for a project. * "/{folder}" quota for a folder. * "/{resource}" quota for a universal resource. * Zero or more quota segmentation dimension. Not all combos are valid. * "/{region}" quota for every region. Not to be used with time intervals. * Otherwise the resources granted on the target is not segmented. * "/{zone}" quota for every zone. Not to be used with time intervals. * Otherwise the resources granted on the target is not segmented. * "/{resource}" quota for a resource associated with a project or org. Here are some examples: * "1/min/{project}" for quota per minute per project. * "1/min/{user}" for quota per minute per user. * "1/min/{organization}" for quota per minute per organization. Note: the order of unit components is insignificant. The "1" at the beginning is required to follow the metric unit syntax. Used by metric-based quotas only.
Generated from protobuf field string unit = 9;
at line 528
RepeatedField
getValues()
Tiered limit values. Also allows for regional or zone overrides for these values if "/{region}" or "/{zone}" is specified in the unit field.
Currently supported tiers from low to high:
VERY_LOW, LOW, STANDARD, HIGH, VERY_HIGH
To apply different limit values for users according to their tiers, specify
the values for the tiers you want to differentiate. For example:
{LOW:100, STANDARD:500, HIGH:1000, VERY_HIGH:5000}
The limit value for each tier is optional except for the tier STANDARD.
The limit value for an unspecified tier falls to the value of its next
tier towards tier STANDARD. For the above example, the limit value for tier
STANDARD is 500.
To apply the same limit value for all users, just specify limit value for
tier STANDARD. For example: {STANDARD:500}.
To apply a regional overide for a tier, add a map entry with key
"
Generated from protobuf field map<string, int64> values = 10;
at line 563
setValues(array|RepeatedField $var)
Tiered limit values. Also allows for regional or zone overrides for these values if "/{region}" or "/{zone}" is specified in the unit field.
Currently supported tiers from low to high:
VERY_LOW, LOW, STANDARD, HIGH, VERY_HIGH
To apply different limit values for users according to their tiers, specify
the values for the tiers you want to differentiate. For example:
{LOW:100, STANDARD:500, HIGH:1000, VERY_HIGH:5000}
The limit value for each tier is optional except for the tier STANDARD.
The limit value for an unspecified tier falls to the value of its next
tier towards tier STANDARD. For the above example, the limit value for tier
STANDARD is 500.
To apply the same limit value for all users, just specify limit value for
tier STANDARD. For example: {STANDARD:500}.
To apply a regional overide for a tier, add a map entry with key
"
Generated from protobuf field map<string, int64> values = 10;
at line 578
string
getDisplayName()
User-visible display name for this limit.
Optional. If not set, the UI will provide a default display name based on the quota configuration. This field can be used to override the default display name generated from the configuration.
Generated from protobuf field string display_name = 12;
at line 592
setDisplayName(string $var)
User-visible display name for this limit.
Optional. If not set, the UI will provide a default display name based on the quota configuration. This field can be used to override the default display name generated from the configuration.
Generated from protobuf field string display_name = 12;